Bollards and Thrust Blocks
Contact and place of performance
Carrie Lawton
13602
Specifications for Bollards Concrete minimum strength 5000psi @ 28days 8 inch Diameter Galvanized Sch40 steel pipe 10 FT long filled with concrete. Set in a 5 ft 8 inch 24 inch Diameter concrete base. Base will have 8 foot concrete on bottom for pipe support. Total length will be 10 Ft 8 inch bollard. Two rebar lifting lug will be set in top of concrete base for setting bollards. Specifications for Thrust Blocks Concrete minimum strength 5000psi @ 28 days Block will be 1Ft 6 inch X 1 Ft 6 inch square Type R anchor lifting lug will installed for set thrust block.
The Department of the Army, specifically the MICC-Fort Drum office, has issued a combined synopsis/solicitation under solicitation number W911S225U2104 for the procurement of bollards and thrust blocks. This requirement is categorized under NAICS 327390, Other Concrete Product Manufacturing, and PSC 3630, Clay and Concrete Products Industries Machinery. The opportunity is designated as an SBA Small Business Administration set-aside, and responses are due by September 23, 2025.
The technical specifications for the bollards require a minimum concrete strength of 5,000 psi at 28 days. Each unit must feature an 8-inch diameter galvanized Schedule 40 steel pipe, 10 feet in length and filled with concrete, set within a 24-inch diameter concrete base that includes an 8-foot concrete bottom for pipe support. The total length of each bollard is 10 feet 8 inches, and the units must include two rebar lifting lugs set into the top of the base for installation.
The thrust blocks must also meet a minimum concrete strength of 5,000 psi at 28 days with dimensions of 1 foot 6 inches by 1 foot 6 inches. Each thrust block must be manufactured with a Type R anchor lifting lug installed for setting the block. Carrie Lawton serves as the point of contact for this solicitation, which currently includes zero attachments.