4520--Lyons VAMC Water Heater Replacement Brand Specific to ensure hookups are compatible no additional piping being considered
Contact and place of performance
Corey Swinton
Lyons, NJ 07939-5001
USA
Qty 1 Patterson-Kelley Model PK-08D Semi-Instantaneous Water Heater rated to provide 27 GPM of Domestic Hot Water from 40-120F when supplied with 25 psig Inlet Steam and 5 psig in the Coil @ 1122#/hr. Heater to be furnished with the following features and controls to meet the specified demand: - Solid Copper Nickel Pressure Vessel rated for 150 psi ASME working pressure. - Factory Insulation. - 90/10 Double Wall Copp...
View moreThe Department of Veterans Affairs has issued this sources sought notice to identify potential providers for the replacement of water heaters at the Lyons VAMC in Lyons, New Jersey. This requirement is classified under NAICS 333414, Heating Equipment (except Warm Air Furnaces) Manufacturing, and PSC 4520, Space and Water Heating Equipment. The agency intends to procure brand-specific equipment to ensure compatibility with existing hookups and to avoid the need for additional piping. Responses to this solicitation, identified by number 36C24226Q0588, are due by May 11, 2026.
The specific equipment requirements include one Patterson-Kelley Model PK-08D semi-instantaneous water heater and one Patterson-Kelley Model PK-10D semi-instantaneous water heater. Both units must feature solid copper-nickel pressure vessels, double-wall copper-nickel tube bundles, and factory insulation. The PK-08D model is required to provide 27 GPM of domestic hot water, while the PK-10D model must provide 65 GPM. Both units include various components such as bronze circulator pumps, Spence pilot-operated steam control valves, temperature and pressure relief valves, and double solenoid high-temperature limit systems with pre-wired control boxes.
The procurement includes factory-authorized start-up, training, and electronic operation and maintenance manuals. Each heater must be supplied on a vertical stand designed to allow for the removal of the heating section without disconnecting domestic water lines. Corey Swinton is the designated point of contact for this notice. One attachment, a document titled 36C24226Q0588.docx, was published with the notice on May 4, 2026.