Name | Type | Posted | Actions |
|---|---|---|---|
RFI Responses (3).xlsx | XLSX | Jan 14, 2026 | |
Solicitation Amendment FA489726R00020003 SF 30.pdf | Jan 14, 2026 | ||
Solicitation Amendment - FA489726R00020003.pdf | Jan 14, 2026 | ||
12_Davis-Bacon Act WD No.ID20260020.txt | TXT | Jan 14, 2026 | |
02_Bldg 2320_SOW (Updated 14Jan26).pdf | Jan 14, 2026 | ||
06 Jan 2026 Sign-in and information.pdf | Jan 14, 2026 | ||
Panel Location Area (Images).pdf | Jan 14, 2026 | ||
Solicitation Amendment - FA489726R00020002.pdf | Dec 19, 2025 | ||
RFI Responses (2).xlsx | XLSX | Dec 19, 2025 | |
Solicitation Amendment FA489726R00020002 SF 30.pdf | Dec 19, 2025 | ||
(11-1) AF3000-Blank.pdf | Dec 19, 2025 | ||
(10) B2320 Drawing.pdf | Dec 19, 2025 | ||
(11) AF3064-example.pdf | Dec 19, 2025 | ||
02_Bldg 2320_SOW (Updated).pdf | Dec 19, 2025 | ||
Solicitation Amendment FA489726R00020002 SF 30.pdf | Dec 1, 2025 | ||
Solicitation Amendment - FA489726R00020002.pdf | Dec 1, 2025 | ||
Nov 3rd Site Visit Sign-In Sheet.pdf | Dec 1, 2025 | ||
(10) Solicitation Amendment FA489726R00020001 SF 30.pdf | Dec 1, 2025 | ||
09_UPGRADE DORMITORY.pdf | Dec 1, 2025 | ||
RFI Responses.pdf | Oct 30, 2025 | ||
Solicitation Amendment FA489726R00020001 SF 30.pdf | Oct 30, 2025 | ||
07_SDSFIE_V_Specification_Document_2016.pdf | Oct 16, 2025 | ||
08_USACE_Design_Submission_Requirements_Manual_2009.pdf | Oct 16, 2025 | ||
06_USACE_Advanced_Modeling_BIMCIM_Object_Standard_2019.pdf | Oct 16, 2025 | ||
05_USACE_AEC_Graphics_Standards_2019.pdf | Oct 16, 2025 | ||
04_USACE_AEC_CAD_Standard_2019.pdf | Oct 16, 2025 | ||
03_Justification and Approval Fire Alarm Panels 17 Dec 21.pdf | Oct 16, 2025 | ||
02_Bldg 2320_SOW.pdf | Oct 16, 2025 | ||
Solicitation - FA489726R0002.pdf | Oct 16, 2025 |
Fire Alarm System Replacement, Mountain Home AFB
Contact and place of performance
Cameron Smith
Mountain Home AFB, ID 83648
USA
Amendment 0003 (04 in SAM) -Solicitation has been extended one final time to allow adequate time for responses to RFI Responses (03) -SOW has been updated to reflect responses to RFIs and site visit remarks. -PSC has been updated. -RFI Responses (03) has been uploaded. The United States Government (USG) has a requirement for design-build services set forth under this contract at Mountain Home Air Force Base (MHAFB) t...
View moreSee attachments below for all relevant documents.
For the proposal, all "if applicable" items shall be priced as if they are all applicable. Any proposals with these items not priced will be deemed unacceptable.
Site Visit:
A site visit for any interested parties will be held on January 6th, 2026 at 2:00 PM MST to walk through the facility and have any questions related to the design-build or technical aspects answered. This site visit is not mandatory, and all relevant questions will be recorded and posted to the solicitation after.
All interested parties will need to meet at the visitor's center at 1:30 PM local (MST) to acquire day passes if you do not have base access already. The visitor's center is located just north of the main gate, on the west side of the highway. If you stay to the right as you approach the base, you can turn into the visitor center's parking lot about 100ft before the manned gate. Attempting to enter the base without a pass will result in a lengthy delay. We will be leaving the visitor's center at 2:00 PM local time (MST).
Per the evaluation factors,
Questions must be submitted no later than 3:00 PM local (Mountain), Jan 12th, 2026
Proposals must be submitted no later than 12:00 PM local (Mountain), Jan 28th, 2026
Questions shall be directed to both POCs.
The Department of the Air Force, through the FA4897 366 CONS PKP, is seeking design-build services to replace an outdated fire alarm system at the Sagebrush Inn, Building 2320, located at Mountain Home Air Force Base, Idaho. This project, identified under solicitation number FA489725R0008, requires the replacement of antiquated panels and devices with a new addressable fire alarm system that meets current Fire Code and Unified Facility Criteria. The scope of work is divided into three phases, beginning with a design phase to reach a 65% design package, followed by construction and demolition, and concluding with testing, commissioning, and close-out. Work must be performed to minimize disruption to the resident Airmen as the building will remain occupied.
This requirement is classified under NAICS code 236220 for Commercial and Institutional Building Construction and PSC code Z2FZ for REPAIR OR ALTERATION OF OTHER RESIDENTIAL BUILDINGS. There is no set-aside for this opportunity, as indicated by the code NONE and explanation NONE. The anticipated period of performance is 407 calendar days from the Notice to Proceed, which includes 212 days for design and 180 days for construction, with the remaining time allocated for demobilization.
The solicitation currently includes 29 attachments, including updated RFI responses, a revised Statement of Work, and Davis-Bacon Act wage determinations. For proposal submission, all items marked as "if applicable" must be priced to be considered acceptable. The response deadline for this opportunity is January 28, 2026, at 12:00 PM Mountain Time. Cameron Smith is the primary point of contact for this requirement.
Generated by Lumen AI
Scoped analysis and attachments—go beyond the summary when you need detail from the solicitation package.